rpcserver: startTime defaults to the unix epoch

Fixes https://github.com/lightningnetwork/lnd/issues/3357.  When
start_time isn't specified, its default value is 0.  This meant when
users explicitly specified a start_time of 0, we would incorrectly set
start_time to 24 hours in the past.  Now, n0 means n0.
This commit is contained in:
tyzbit 2019-10-03 18:12:21 -04:00
parent 4cb30001ac
commit 8891346cb2
2 changed files with 3 additions and 8 deletions

View File

@ -3532,7 +3532,7 @@ var forwardingHistoryCommand = cli.Command{
payment circuits (HTLCs) over a particular time range (--start_time and
--end_time). The start and end times are meant to be expressed in
seconds since the Unix epoch. If --start_time isn't provided,
then 24 hours ago is used. If --end_time isn't provided,
then the Unix epoch (01-01-1970) is used. If --end_time isn't provided,
then the current time is used.
The max number of events returned is 50k. The default number is 100,

View File

@ -4637,13 +4637,8 @@ func (r *rpcServer) ForwardingHistory(ctx context.Context,
numEvents uint32
)
// If the start time wasn't specified, we'll default to 24 hours ago.
if req.StartTime == 0 {
now := time.Now()
startTime = now.Add(-time.Hour * 24)
} else {
startTime = time.Unix(int64(req.StartTime), 0)
}
// startTime defaults to the Unix epoch (0 unixtime, or midnight 01-01-1970).
startTime = time.Unix(int64(req.StartTime), 0)
// If the end time wasn't specified, assume a default end time of now.
if req.EndTime == 0 {